三菱地所設計 YEAR BOOK 2023
27/32

Year Book 2023Engineering地球環境保護への直接的貢献社会的要請への対応(ISO14000シリーズ他)時代に追従するフレキシブルな業務環境災害等に配慮したBCP対策健康経営がもたらす安定した収益制振スリット(Damped slit)架構概念図。外壁の各コーナー部とセンターに、制振スリット(ダイヤ状の架構の一部をダンパーに置き換えた部分)が設けられている。Conceptual diagram of the structure. Damped slits (areas where some of the diagrids are replaced by dampers) are installed at corners and centers on the exterior wall.Super-Tall Building Realized with Damped Braced Tube SystemIntegration of Architecture and Facilities Based on Environmental Concepts027027As a super-tall building, TOKYO TORCH Torch Tower (about 390 m tall, planned completion in FY2027) is required to have earthquake-proof performance far exceeding conventional concepts. For this reason, we proposed and designed damped braced tube system, which combines high rigidity and high damping. The system is based on a braced-tube structure with high horizontal rigidity created by flexural rigidity (outer-shell structure using the whole building as one) and shear rigidity (brace structure leveraging diagonal members), and bending deformation is concentrated along the damped slits, where dampers replace braces, to eff ectively control the building’s vibration. The response value verifi cation indicates that vibration can be reduced to less than half of that of a building with only elastic bracing. In addition, the system greatly improves wind resistance, ensuring an extremely high level of habitability and safety despite being the tallest building in Japan.For Fukuda Denshi Hongo Offi ce (Bunkyo City, Tokyo, completed in 2021), our mechanical specialists joined the project from an early stage and worked with the client to develop the environmental concepts (see image below). Diff erent specialists collaborated under the concepts to integrate architectural and mechanical designs at a high level. For energy saving measures, we took a seamless hierarchical approach, with “reduction of environmental load through building design” at the top, followed by “active use of natural energy” and, finally, “improving mechanical equipment efficiency.” The mechanical cores on the east and west and eaves on the south and north block sunlight. Inside the building, ceiling radiant cooling and LED line lighting fi xtures were installed above the beam bottom to realize a comfortable offi ce space through the coherent design. These efforts allowed the building to achieve an annual primary energy reduction equivalent to ZEB Ready based on the actual performance. The project leveraged the collective capabilities of a comprehensive design fi rm.社員の快適性・健康状態に配慮した企業姿勢病欠等の業務機会ロス抑制作業効率・帰属意識の向上地球環境の健康に貢献地球環境に配慮した企業姿勢安心・安全で健康な安定した経営環境の構築「フクダ電子本郷事業所」(東京都文京区、2021年竣工)では、計画早期から当社の設備職能者が参画して「環境コンセプト」(下図)を施主と策定。そのもとで各職能が連携し、建築と設備、両計画の高度な融合を図りました。省エネルギー対策においては「建築計画による負荷削減」を上位に置き、次に「自然エネルギーの積極的利用」、最後に「設備機器の高効率化」とシームレスな階層別アプローチを実施。東西面の設備コアと南北面の庇が日射を制御する建物の内部、梁底より高い位置に天井放射冷房・LEDライン照明器具を導入して、一貫性あるデザインで快適な執務空間を実現しました。こうした試みにより、実績値ではZEB Ready相当の年間一次エネルギー削減を達成。組織設計事務所の総合力を生かしたプロジェクトです。超々高層ビルとして、従来の概念をはるかに上回る耐震性能が求められる「TOKYO TORCH Torch Tower」(高さ約390m、2027年度竣工予定)では、《高剛性》と《高減衰》を併せ持つ「外殻制振構造」を提案・設計しています。これは、曲げ剛性(建物全体を一体で利用する外殻構造)とせん断剛性(斜め材を活かしたブレース構造)による高い水平剛性を有するブレースチューブ構造をベースに、ブレースをダンパーに置き換えた「制振スリット」へ曲げ変形を集約して効果的に制振を行うものです。応答値の検証では、全体を弾性ブレースとした場合の半分以下に抑えられることが示されました。耐⾵性能も大きく向上し、日本一の高さながら居住性・安全性を極めて高いレベルで確保します。Wellness健康に活き活きと働くEcologyHealthy健康の確保Safety経営基盤「外殻制振構造」による超々高層ビルの実現環境コンセプトに基づく建築と設備の融合

元のページ  ../index.html#27

このブックを見る